Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter

Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter

Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter
video
Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter
Product Details:
Place of Origin: China
Brand Name: Lanry
Certification: ISO9000, CE, CPA,CMC
Model Number: TF1100-CH
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: carton packing 44X33X22cm 1PC/carton
Delivery Time: 7-10 working days
Payment Terms: T/T
Supply Ability: 1000pcs/month
Contact Now
Detailed Product Description
Flow Velocity Range: 0.01 To 12m/s, Bi-directional Type: Handheld
Response Time: 0.5s Power Supply: AC:85-265V Up To 14 Hours With Fully Charged Internal Batteries
Communication: OCT, RS232 ,Logged Data Degree Of Protection: IP68
High Light:

IP68 Ultrasonic Flow Meter

,

12m/s Ultrasonic Flow Meter

,

OCT Ultrasonic Water Meter

 

Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH


Transition time ultrasonic flowmeter working method. The battery is rechargeable for 14 hours, and the 4-line backlight display makes the reading more intuitive. The clamp-on ultrasonic sensor (sensor) is installed on the outer surface of the pipeline and is used for non-invasive and non-invasive flow measurement of the liquid and liquefied gas filled in the pipeline. Three pairs of sensors are sufficient to cover the most common pipe diameter ranges. The user can hold and operate the flow meter host by hand. This flexible and easy-to-use flow meter is an ideal tool to support service and maintenance activities. It can also be used to control or even temporarily replace permanently installed instruments.

 
Flow Rate Calibration Ultrasonic Flow Measurement TF1100-CH​ Features:
 
1.14 hours battery (rechargeable), back-lit 4 lines display.
2.Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
3.Non-invasive transducers.
4.Data logger function.
5.Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
 

Flow Rate Calibration Ultrasonic Flow Measurement Applications:
 
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Refrigeration and air conditioning systems

Metallurgy and mining applications
Food , beverage and pharmaceutical industry
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
 
General


 ● Service and maintenance
● Support of commissioning process and installation
● Replacement of defective devices
● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves
 
Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 0 
 
Specifications: Transmitter

Measurement principle Ultrasonic transit-time difference correlation principle
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Flow velocity range 0.01 to 12 m/s, bi-directional
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V Up to 14 h with fully charged internal batteries
Enclosure type Handheld, Portable
Degree of protection IP65 according to EN60529
Housing material ABS( UL 94HB)
Operating temperature -20℃ to +60℃
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display

 
Specifications: Transducer
 

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Material of transducer Aluminum for standard temp. sensor, and peek for high temp. sensor
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Transducer Size Type S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*33(d)mm
Type L 80(h)*40(w)*42(d)mm
Cable Length Std: 5m

 
Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...
 
Dimensional Sketches
 
Transmitter:
Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 1
Transducer:
 
Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 2
 

Packing & Delivery

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 3Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 4Non invasive 12m/s IP68 Transit Time Ultrasonic Flow Meter 5

Delivery

Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application